The lock desktop swallows keyup, so a hold-to-talk recording never ended,
the first shortcut after unlocking was dropped as auto-repeat, and Win from
Win+L made the next suggestion accept wait out the full 1.5s modifier timeout.
On powerMonitor lock-screen/suspend the chord machine now emits released for
emitted triggers and clears its state, and modifier tracking forgets held keys.